audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Turbocharger Recirculating Valve (N249), checking|Page 3651 > < Turbocharger Recirculating Valve (N249), checking
Page 2
background image

Specified value: 20 to 30 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace the Turbocharger Recirculating Valve ( N249).

If the specification was obtained:

Checking Voltage supply

-

Using a multimeter, check the Turbocharger Recirculating Valve (N249) electrical harness connector terminal 1 to Ground (GND) for voltage.

-

Operate the starter briefly.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

-

Check the Turbocharger Recirculating Valve (N249 ) electrical harness connector terminal 1 to the Motronic Engine Control Module (ECM)
Power Supply Relay (J271) socket 2/87 for an open circuit, short circuit to each other, Battery (+), or Ground (GND).

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.