audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Damaged Side Window|Page 9827 > < Damaged Side Window|Page 9825
Page 1
background image

Quarter Window Glass: Service and Repair
Side Window

Side Window

Installing

-

After the preparatory work has been performed, cut nozzle tip as shown in illustration.

‹› Dimension - a - 12 mm

‹› Cross-section thickness of adhesive bead is determined by dimension of opening in nozzle tip and rate of application.

Dimensions for adhesive application:

1. Adhesive sealing material

2. Primer

3. Window

‹› Dimension - a - = 8 mm +2 mm

‹› Dimension - b - = 12 mm +3 mm

‹› Distance - c - = to window edge is given through the window molding.

-

Position complete surface of nozzle - 2 - onto window. 