audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Camshaft Adjustment Valve 1|Page 1311 > < Variable Valve Timing Actuator|Testing and Inspection|Page 1308
Page 1
background image

Variable Valve Timing Actuator: Service and Repair
Camshaft Adjustment Valve 1

Camshaft Adjustment Valve 1

Special tools, testers and auxiliary items required

‹› Torque wrench (V.A.G 1783)

‹› Torx bit assortment (V.A.G 1766)

‹› Ratchet 1/4" (VAS 6234)

‹› Spring-type clip pliers (VAS 5024 A)

Removing

‹› Always replace gaskets and seals.

-

Disconnect electrical connector on Mass Air Flow (MAF) Sensor (G70) - 3 -.

-

Open clips - 1 and 2 - and remove air guide hose from mass air flow sensor.

-

Remove front air intake connector on lock carrier - 4 -

-

Remove engine cover.

-

Separate electrical connector - 1 -.

Camshaft Adjustment Valve 1|Page 1311 > < Variable Valve Timing Actuator|Testing and Inspection|Page 1308