Read-out examples:

‹› Range A, 30° C equals a resistance of 1.5 to 2.0 kohms

‹› Range B, 80° C equals a resistance of 275 to 375 Ohms

If any of the specified values are not obtained:

-

Replace the Intake Air Temperature (IAT) Sensor ( G42).

°°Testing if display approx. -40 C or approx. -46 C:

-

Disconnect the Intake Air Temperature (IAT) Sensor (G42) electrical harness connector - arrow -. 

-

Using a jumper wire, connect the Intake Air Temperature (IAT) Sensor (G42) electrical harness connector terminals 1 to 2.

-

 Check the value indicated on the scan tool display.