Page 2
background image

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) terminals 3 to 4 for resistance. 

Specified value: 2.5 to 10.0 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace the Heated Oxygen Sensor (HO2S) (G39). Refer to 2.0 Liter 4-Cyl. 4V Turbo Fuel Injection & Ignition, Engine Code(s): BWA. Repair
Group 24.

If the specification was obtained:

Checking voltage supply

-

Crank the engine (engine may run).

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminal 4 to Ground (GND) for voltage.

-

Switch the ignition off.

Specified value: Battery voltage.

If the specification was not obtained:

-

Check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminal 4 to the Motronic Engine Control Module (ECM) Power
Supply Relay (J271) socket 2/87 an open circuit, a short circuit to each other, Battery (+), or Ground (GND). 

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If the specification was obtained:

Checking Ground (GND) activation

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. Refer to 2.0 Liter 4-Cyl. 4V Turbo Fuel Injection & Ignition, Engine Code(s): BWA. Repair Group 24.

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Engine Control Module (ECM) (J623). Refer to => [ replacing ] See: Engine Control Module/Testing and Inspection/Engine Control
Module (ECM) (J623).

Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 2303 > < Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 2301