audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 2467 > < Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 2465
Page 2
background image

Checking internal resistance

-

Disconnect the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector -  arrow -.

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminals
1 to 2 for resistance.

Specified value: 1.0 to 20.0 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) ( G130). 

If the specification was obtained:

Checking voltage supply

-

Crank the engine (engine may run).

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) ( G130) electrical harness connector terminal
1 to Ground (GND) for voltage. 

Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 2467 > < Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 2465