audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Leak Detection Pump (LDP) (V144), checking|Page 2544 > < Leak Detection Pump (LDP) (V144), checking
Page 2
background image

If any of the specifications are not obtained:

-

Replace the Leak Detection Pump (LDP) (-V144- ).

If the specified values are obtained:

Checking voltage supply

‹› The voltage for the Leak Detection Pump (LDP) (-V144- ) is supplied by the Motronic Engine Control Module (ECM) Power Supply Relay (J271)

OK.

-

Using a Multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical harness connector terminal 3 for voltage.

-

Operate the starter briefly.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

Leak Detection Pump (LDP) (V144), checking|Page 2544 > < Leak Detection Pump (LDP) (V144), checking