background image

-

Set slide ring - 1 - on hand vacuum pump (VAS 6213) to position - B - for " pressure".

CAUTION!
The pressure must not exceed 750 mbar. If the pressure is exceeded, the vacuum diaphragm can be damaged.

-

Operate Hand Vacuum Pump (VAS 6213) several times and observe rods.

The linkage - A - must move approx. 300 mbar and be at approx. 700 mbar at end position.

Actuator lift is approx. 10 mm.