audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Expansion Valve|Testing and Inspection|Page 5485 > < Expansion Valve|Testing and Inspection
Page 2
background image

‹› An adapter cable can also be used for this test. To do this, e.g. use one connector each - A - and - B - (part number 1J0 973 702 and 1J0 973 802

and relevant terminal contacts), two standard sockets for banana connectors - C - and two wires with 0.5 mm 2 diameter.

-

Connect DSO Measuring Leads 1 & 2 (VAS 5051/8 ) to the adapter leads.

-

Measuring lead (signal wire) to terminal - 2 - of connector - B -

-

Measuring lead (shielding, Ground) to terminal - 1 - of connector - B -

-

Set operating mode Test Instruments DSO (Digital Storage Oscilloscope) on Diagnostic Operation System (VAS 5051 A).

-

Then select the 5 V/Div = 0.5 ms/Div (5V DC and 0.5 milliseconds per unit) setting.

-

Start the engine.

-

Set temperature preselect on Climatronic Control Module (J255) to "Cold" setting (maximum cooling performance)

-

On Climatronic Control Module (J255) A/C control head, switch activation of A/C Compressor Regulator Valve (N280) on and off by pressing the
"AC" button (with indicator light when compressor is on).

Shown on screen of oscilloscope, depending on setting of Climatronic Control Module (J255) A/C control head:

-

In operating mode "OFF" or "AC off" (indicator light in "AC" button does not come on), no square wave signal (the A/C Compressor Regulator
Valve (N280) is not activated).

-

In operating mode "Auto" and "AC on" (indicator lights in buttons come on) and temperature preselect at "Cold" setting (maximum cooling
output), a square wave signal with an impulse width -  A - between 75 % and 100 % (the control valve is activated).

Expansion Valve|Testing and Inspection|Page 5485 > < Expansion Valve|Testing and Inspection