audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Variable Induction Position Sensor|Testing and Inspection|Page 2833 > < Variable Induction Position Sensor|Testing and Inspection
Page 2
background image

-

Disconnect the Intake Flap Motor (V157)/Intake Manifold Runner Position Sensor (G336) electrical harness connector - arrow -.

-

Switch the ignition on.

-

 Using a multimeter, check the Intake Flap Motor (V157)/Intake Manifold Runner Position Sensor (G336) electrical harness connector terminals 1
to 3 for voltage. 

Specified value: about 5 V

-

Switch ignition off.