If the specification was obtained:

Checking Voltage supply

-

Using a multimeter, check the Turbocharger Recirculating Valve (N249) electrical harness connector terminal 1 to Ground (GND).

-

Operate the engine briefly.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

-

Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the wiring connection. 

If no malfunctions are found in the wiring:

Checking wiring

If the manufacturers test box is being used, perform the following step.

-

Install the test box.

If the manufacturers test box is not being used, perform the following step.

-

Remove the Motronic Engine Control Module (ECM) (J623). 

-

Using a multimeter, check the Turbocharger Recirculating Valve (N249) electrical harness connector terminal 2 to Motronic Engine Control
Module (ECM) (J623)electrical harness connector T60 for an open circuit.