Switch ignition off.

If the specified value was not obtained:

-

Check and/or repair wiring as required.

If the specified value was obtained:

Checking internal resistance

-

Using a multimeter, check the Intake Flap Motor ( V157)/Intake Manifold Runner Position Sensor ( G336) electrical terminals 2 to 3 for
resistance.

Specified value: 7-25 ohms (at approx. 20° C)

-

Using a multimeter, check the Intake Manifold Runner Position Sensor (G336) electrical terminals 1 to 3 for resistance. 

Specified value: 244 [+/- 40] ohms (at approx. 20° C)

If the specified values were not obtained:

-

Replace the Intake Flap Motor (V157)/Intake Manifold Runner Position Sensor (G336). 

If the specified value was obtained:

Checking wiring

If the manufacturers test box is being used, perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used, perform the following step.

-

Remove the Motronic Engine Control Module (ECM) ( J623).

-

Using a multimeter, check the Intake Flap Motor ( V157)/Intake Manifold Runner Position Sensor ( G336) electrical harness connector terminals
to the Motronic Engine Control Module (ECM) (J623) electrical harness connector T60 terminals for an open circuit.

Specified value: 1.5 ohms Max.

If the specification was not obtained:

-

Check the wiring for a short circuit to Battery (+), or an open circuit.

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring:

-

Replace the Motronic Engine Control Module (ECM) (J623).

-

Install the engine cover with air filter.

Final procedures

Intake Air Switch-Over Valve, Checking|Page 2897 > < Intake Air Switch-Over Valve, Checking|Page 2895