Page 10
background image

-

Remove generator => Electrical Equipment 27 Generator.

-

If present, press the protective cap off the generator pulley.

-

Counterhold mounting nut using socket (3310) and rotate generator shaft clockwise to loosen it.

-

Remove ribbed belt pulley.

Installing

Install in reverse order of removal, observing the following:

-

Turn the generator shaft counterclockwise to tighten.

-

Clip protective cap onto generator pulley.

Tightening torque

Ribbed Belt Pulley with Freewheel, Removing and Installing

Special tools, testers and auxiliary items required

‹› Multi-point adapter (3400)