audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Direct Shift Gearbox Mechatronic|Page 3321 > < A/T - No Acceleration When Selecting 'D,R,S' From Park
Page 1
background image

Shifter A/T: Testing and Inspection
Direct Shift Gearbox Mechatronic

Direct Shift Gearbox Mechatronic Voltage Supply, Checking

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› The Direct Shift Gearbox (DSG) Mechatronic (J743 ) fuses OK.

‹› The Power Supply Relay (terminal 15) ( J329) OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Selector lever in "P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to =>  See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Modes 01 - 09/Diagnostic Mode 09 - Read Vehicle Information

Start diagnosis

-

Disconnect the Direct Shift Gearbox (DSG) Mechatronic (J743) electrical harness connector - 1 - by rotating counterclockwise.

Checking voltage supply, terminal 30

-

Using a Multimeter, check the Direct Shift Gearbox (DSG) Mechatronic (J743) electrical harness connector terminals for voltage.

Direct Shift Gearbox Mechatronic|Page 3321 > < A/T - No Acceleration When Selecting 'D,R,S' From Park