Refrigerant: Service and Repair

CAUTION:

Do not leave the A/C system open for a long period of time. Prolonged exposure to the air will contaminate the system and will require the
replacement of certain A/C components (restrictor, accumulator, etc.).

1. Disconnect power supply from compressor clutch (for example, remove connector from high pressure cut-out switch F118) to prevent damage to

system if compressor is accidentally switched On with refrigerant system discharged.

Accumulator With Service Valve

2. Close both valves on A/C manifold gauge set, then connect hose 1 from low pressure gauge to low pressure service valve on accumulator.
3. Remove A/C refrigerant high pressure switch F23 in A/C line between condenser and evaporator to expose high pressure service valve.
4. Connect hose 3 from high pressure gauge to high pressure service valve, then the manifold gauge hose 2 to inlet connection 4 on refrigerant

recovery/recycling unit 5.

5. Follow refrigerant recovery/recycling unit manufacturer's instructions to discharge A/C system into recovery/recycling unit.
6. Close manifold gauge valves when refrigerant is fully discharged.