Fuse: All Technical Service Bulletins
Climate Control - Inoperative, Fuse S17 Blows

Group: 97

Number: 93-01

Date: March 31, 1993

SUBJECT: 
Climate Control Inoperative,
Fuse S17 blows intermittently

MODEL(s): 
V8 1990 - 1991 m.y.

CONDITION

Fuse 517 (20A) for climate control blows intermittently for no obvious reasons.

SERVICE

Normal current draw for this circuit may be as high as 22A.

-

Check wiring for short circuit. If no short circuit is found, install a 30A fuse in place of the original 20A fuse.