1 Series E81 116i (N43) 3-door
•
Desired temperature value is increased or reduced
> E70 High
The influence on IHKA regulation by the solar sensor is assigned separately to the driver's side and to the front-
passenger side.
> E81, E82, E87, E90, E91, E92, E93 IHKA
How the solar sensor affects the IHKA regulation on the driver's side and on the front-passenger side is not
programmed separately.
MAX cooling (IHKA only)
The MAX button makes it possible for the user to select maximum cooling with just one press of a button at the
IHKA controls.
When the MAX button is pressed, all functions, including the defrost function, are deactivated. The air-
conditioning function is activated (if it was not already activated) and defined settings are selected
(e.g. temperature control is deactivated, ventilation flaps are fully opened).
Residual heat (IHKA only)
The residual-heat function allows the waste heat from the engine to be used to heat up the vehicle interior when
the engine is not running (e.g. during a stop at a level crossing). The residual-heat function is only possible for a
certain run-down period (15 minutes from terminal 15 OFF). The auxiliary water pump is activated to circulate
the water.
Switch-on conditions:
•
Terminal 15 OFF
and
•
Run-down period active (up to 15 minutes after terminal 15 OFF)
and
•
REST button* in IHKA controls ON
and
•
Ambient temperature below 25
°
C
and
•
Engine temperature at some point above 60
°
C
and
•
On-board supply voltage over 11.4 volts
Condition for switching off:
•
Terminal 15 ON
or
•
Residual heat ON (15 minutes) expired
or
•
REST button* in IHKA control panel OFF
or
•
OFF condition activated with residual heat active (terminal R)
or
•
Prompt from power management to switch off auxiliary consumers
SBT Integrated heating control and air-conditioning system E70, E81, E82, E87, E90,
BMW AG - TIS
16.01.2013 05:49
Issue status (12/2007) Valid only until next DVD is issued
Copyright