Release oxygen monitor sensor with special tool 11 4 260 .
Tightening torque 11 78 1AZ
.
Installation:
The threads of new oxygen monitor sensors are already
coated with Never Seez Compound.
If an oxygen monitor sensor is reused, only apply a thin and
uniform coat of Never Seez Compound (refer
to BMW Parts Service) to thread.
Oxygen monitor sensor section projecting into exhaust system
branch must not be cleaned or come into contact with
lubricant.
Installation:
Cover (mask) oxygen monitor sensor when applying underseal.
Pay attention to cable routing of oxygen monitor sensor.
Check function of DME.
RA Replacing oxygen monitor sensor (after main catalytic converter) (N45T)
BMW AG - TIS
17.01.2013 15:39
Issue status (12/2007) Valid only until next DVD is issued
Copyright