61 20 900

Disconnecting and connecting battery
negative lead

Warning!

Observe safety instructions for handling vehicle battery.

Follow instructions for disconnecting and connecting battery.

Observe notes on power supply / on intelligent battery sensor
(IBS).

Necessary preliminary tasks:

Remove luggage compartment floor trim

Version with intelligent battery sensor (IBS):

Loosen nut (1). Tightening torque  61 21 1AZ

.

 

Important!

Do not under any circumstances use force to pull off pole
shoe.

Do not under any circumstances release socket head cap
screw of IBS (2).

 

Detach battery negative lead (3) with IBS (2) in upward direction
from battery, lay to one side and secure.