Connect special tool 13 8 010 to diagnosis connector, switch on
ignition and operate special tool to activate high-pressure non-
return valve.
Caution!
Be sure to remove special tool 13 8 010 prior to test run, as
otherwise malfunctions can occur during driving operation.
Connect special tool 16 8 010 to filler connection. Connect hose
to workshop compressed air circuit (dehumidified air).
Check screw connection (1) for leaks with leak tester spray.
Check connection on high-pressure relief valve with 14 bar switch
for leaks with leak tester spray.