Lower the coolant water level.

Disconnect preheating hose from flange for pressure regulating
valve.

Removing flange for pressure-control valve.

Installation:

Check dowel sleeves (1) for damage and correct installation
position.

Replace the seals above and below the flange for the
pressure regulating valve.

Separate the plug connections for the camshaft sensor and the
crankshaft sensor at the cable duct. 

Release the cable duct from the lower housing of the collector.

Separate the screw connections for the alternator and the starter.

Unfasten lower section of manifold and remove from stud bolts
until plug connections for oil pressure switch and temperature
sensor for coolant are accessible.

Disconnect plug connections for oil pressure switch and
temperature sensor for coolant.

Remove the lower housing of the collector.

Note:

Bracket (1) for the plug connection of the knock sensors.

RA  Removing and installing lower section of manifold (M44)