background image

13 51 005

Adjusting injection pump statically (DDE 2)
(M41)

Connect DIS or MoDiC to diagnosis connector, select
diagnosis program on the DDE control unit, select special
functions or test module, then interrogate the fault memory
of the DDE control unit.

Switch off ignition.

Note instructions on disconnecting/connecting battery,

refer to General Data MG 12

Disconnect and mask positive battery lead.

Coolant temperature > 20

°

  C

Remove drain plug (1).

Installation:

Always replace seal.

Tightening torque, refer to Technical Data 13 51 1AZ

Install special tool 13 5 330. Secure dial gauge under preload.

RA  Adjusting injection pump statically (DDE 2) (M41)

BMW AG - TIS

06.02.2013  21:31

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -