bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

1 RA Brief Description Of The Test Functions|Page 2290 > < 1 RA Brief Description Of The Test Functions|Page 2288
Page 3
background image

Test 14 Perform software reset

(watchdog test) or complete reset acts like a power interrupt. When executing the function, a RESET is initiated, the
diagnosis level is quit and lock ON is activated.

If implausible faults occur, the test should be conducted before any components are replaced.

The test mode is quit automatically.

Test 15 Lock off / Lock on

This function is preset to Lock ON when the test function is switched on. To change over, button must be held down
while selecting.

The display then switches every 3 seconds from L ON to L OFF.

Once desired status is reached, release the button.

Test 00 Termination of cluster diagnosis (test function)

and return to normal operation.

Fuel-gauge setting

Hex value

1st Dash A

0d

End of spare

37

2. Dash B

54

3. Dash C

90

4. Dash D

c4

5. Dash E (full)

f0

Temp.-pointer setting 

Hex value

1st Dash A

ce

2. Dash B

6d

3. Dash C

5c

4. Dash D (centre)

4f-23

5. Dash E

1e

6. Dash F

18

RA  Brief description of the test functions:

BMW AG - TIS

07.02.2013  05:08

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 3 -

1 RA Brief Description Of The Test Functions|Page 2290 > < 1 RA Brief Description Of The Test Functions|Page 2288