bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

2 RA Replacing Camshaft (M50 VANOS)|Page 501 > < 2 RA Replacing Camshaft (M50 VANOS)|Page 499
Page 9
background image

You must adhere to the following waiting periods after installing
the camshaft and before cranking the engine back to the TDC
position.

Room temperature (20

°

C) 4 mins

10

°

C ... 20

°

C  11 mins

°

C ... 10 

°

C  30 mins

Install camshafts with tips on intake and exhaust valves pointing
towards 1st cylinder.

Fit bearing cover.

Note:

The bearing covers are clearly marked and can be read from
the exhaust end:

A1 ... A7 for the exhaust end

E1 ... E7 for the intake end

Fit special tool 11 3 260 to cylinder head and screw into spark
plug threads in cylinders 1 and 4.

Tightening Torque,

refer to Technical Data 12 12 1AZ

RA  Replacing camshaft (M50 VANOS)

BMW AG - TIS