bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

18 Exhaust System (M52) > < 1 SI Low Coolant Level E36 E38 E39 With M52 Engine
Page 2
background image

In vehicles fitted with a latent-heat accumulator, follow the special bleeding routine
specified.

See Repair Instructions 64 12 ...

In vehicles fitted with independent heating, follow the additional bleeding routine.

See Repair Instructions 64 12 ...

The coolant mixture ratio (glycol : water) of 50 : 50 must under no circumstances  be
exceeded. 
Reason:
An impermissibly high concentration of glycol binds any residual air still in the cooling
system, thus delaying elimination of the residual air during engine operation.
Moreover, the thermal conductivity of the coolant is reduced as the glycol concentration
increases.
However, if the mixture ratio of 50 : 50 is not adhered to, with more water than glycol being
poured in, the level of corrosion protection over the 3-year change interval specified is no
longer guaranteed.
Guide values for measuring the concentration:
glycol : water = 50 : 50 corresponds to anti-freeze protection down to - 40 

°

C

glycol : water = 40 : 60 corresponds to anti-freeze protection down to - 30 

°

C

SI  Low coolant level E36 E38 E39 with M52 engine

BMW AG - TIS

09.02.2013  11:39

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

18 Exhaust System (M52) > < 1 SI Low Coolant Level E36 E38 E39 With M52 Engine