background image

24 11 055

Removing and installing/sealing transmission
extension (A4S 270R/ 310R)

Remove propeller shaft,

refer to 26 11 000.

Remove output flange.

Hold output flange with special tool 23 0 020.

Unscrew collar nut with a wrench socket.

Pull off output flange.

Pull plug off of speed sender.

Remove transmission extension.

Unscrew bolts with special tool 24 5 180.

Caution!

Bolts have inch threads.

Remove transmission extension and seal.

Locate seal in position with grease (Vaseline).

Mount transmission extension.

Guide operating rod (1) for parking lock into pawl (2).

Caution!

Only use bolts with inch threads.

Tightening torque,

refer to Technical Data 24 11 1AZ.

Mount and bolt output flange.

Tightening torque,

refer to Technical Data 24 21 1AZ.

RA  Removing and installing/sealing transmission extension (A4S 270R/ 310R)