bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

7 RA Replacing Magnetic Coupling For Compressor (with Seiki Compressor)|Page 2656 > < 6 RA Replacing Air Conditioning Compressor (M50, M52)|Page 2654
Page 1
background image

64 52 551

Replacing magnetic coupling for compressor
(with Seiki compressor)

Note:

Removing compressor,

refer to 64 52 520

Grip drive plate with special tool 64 5 020, unfasten screw (1)
and remove drive plate.

Installation:

Ensure correct clearance A (0.5 ... 0.8 mm) between drive
plate and pulley. If necessary, adjust by installing shims.

Only M43:

Installation:

Secure magnetic measuring block and dial gauge to vice.

Connect adapter cable 61 2 070 to a battery. Connect adapter
cable 61 1 467 to the magnetic coupling. Supply magnetic
coupling with power via safety cable 61 1 476 and read off
pointer reading on dial gauge when doing so. If necessary, adjust
clearance (0.5 ... 0.8 mm) between drive plate and pulley using
shims.

RA  Replacing magnetic coupling for compressor (with Seiki compressor)

BMW AG - TIS

10.02.2013  01:09

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

7 RA Replacing Magnetic Coupling For Compressor (with Seiki Compressor)|Page 2656 > < 6 RA Replacing Air Conditioning Compressor (M50, M52)|Page 2654