Note:
To unfasten and tighten down the lateral hydraulic leads,
special tool 34 3 172 can be used to overcome access
problems.
Unfasten hydraulic leads (1 ... 2) and remove hydraulic unit.
Note:
Seal connection bores with suitable plastic caps.
Installation:
Tightening torque,
refer to Technical Data 21 52 1AZ.
RA Removing and installing/replacing hydraulic unit (SMG)