bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

90 Troubleshooting > < 2 RA Replacing Pressure Accumulator (SMG) For Hydraulic Unit
Page 1
background image

21 53 501

Checking/topping up oil level in hydraulic
system (SMG)

Switch on ignition.

Actuate brake.

Shift selector lever from position "0" to "R" and/or "0" to "E" until
the charge pump on the hydraulic unit (1) cuts in.

Wait until charge pump switches off.

Open up expansion tank (1).

Open bleed screw (3) on reservoir until hydraulic fluid emerges.

Close bleed screw (3).

Fill expansion tank (1) up to MAX mark (dipstick (4) on cover) with
hydraulic fluid (Pentosin CHF 11S).

RA  Checking/topping up oil level in hydraulic system (SMG)

BMW AG - TIS

09.02.2013  23:27

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

90 Troubleshooting > < 2 RA Replacing Pressure Accumulator (SMG) For Hydraulic Unit