3 Series E36 Z3 coupe (M52) COUPE
Disconnect plug connector (2) of activated carbon canister non-
return valve (1) and pull off.
Installation:
Ensure proper locking of plug connector.
Connect special tool 12 6 410/411 to activated carbon canister
non-return valve and vehicle battery. Activated carbon canister
non-return valve is closed by applying 12-volt vehicle voltage.
Caution!
Ensure sufficient vehicle voltage, do not reverse terminals.
Remove tank filler cap and connect special tool 16 1 150 to tank
filler neck.
Screw in rear towing eye and hook special tool 16 1 150 into it.
Connect special tool to workshop compressed air system (8 - 10
bar) with compressed air hose (1).
Connect pressure sensor (Diagnosis Information System) with
measuring range of 0-3.5 bar.
Caution!
Make sure that the pressure regulator on special tool
16 1 150 is set completely in the "-" direction and the non-
return cock between the pressure regulator and the pressure
sensor is closed.
RA Checking fuel tank and tank ventilation system for leak-tightness
BMW AG - TIS
11.02.2013 02:50
Issue status (12/2007) Valid only until next DVD is issued
Copyright