bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

3 RA Checking Cooling System For Water Leaks > < 2 RA Draining And Topping Up Coolant|Page 738
Page 3
background image

Integrated expansion tank

Unfasten vent screw on expansion tank.

All bleeding occurs through vent plug on expansion tank. 

Cooling system is vented after the filling procedure.

M40

Loosen additional vent screw on thermostat housing.

M52

On vehicles with M52 engines, also unfasten additional vent
screw.

Note:

Before filling, switch on ignition, set heater control to
maximum temperature and set fan to low speed. This opens
heating valves and installed auxiliary water pump runs if
necessary.

Perform filling operation slowly.

Fill expansion tank completely and wait until coolant emerges at
vent point(s) without bubbles. Close bleed screw(s).

Note:

Only use specified coolant, refer to Operating Fluids
Specification MG 17

RA  Draining and topping up coolant