bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

2 RA Replacing Crankshaft Pulse Generator (N42, N40, N46, N45, N43) > < 8 RA Replacing Ignition Coils (N42, N40, N46, N45)|Page 797
Page 1
background image

11 37 700

Replacing control unit (Valvetronic) 

Necessary preliminary tasks:

Follow instructions for disconnecting and connecting battery.

Remove battery.

Follow instructions for removing and installing electronic

control units.

Observe following instructions before replacing control unit:

Code control unit.

Program control unit.

Release screws.

Remove plate (1).

Note:

For purposes of clarity, this work step is shown on a Valvetronic
control unit.

Unlock plug connections on Valvetronic relay (1) and on
Valvetronic control unit (2) and disconnect.

Remove Valvetronic control unit (2).

Check function of DME.

RA  Replacing control unit (Valvetronic)

BMW AG - TIS

20.01.2013  19:13

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

2 RA Replacing Crankshaft Pulse Generator (N42, N40, N46, N45, N43) > < 8 RA Replacing Ignition Coils (N42, N40, N46, N45)|Page 797