bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

2 RA Replacing Oxygen Monitor Sensor (after Primary Catalytic Converter) (N42_N46)|Page 768 > < 1 RA Replacing Both Oxygen Control Sensors (N42_N46)|Page 766
Page 1
background image

11 78 611

Replacing oxygen monitor sensor (after
primary catalytic converter) (N42/N46)

Special tools required:

11 7 030

11 9 150

Warning!

Scalding hazard!

Only perform this task on an engine that has cooled down.

Unclip cable and plug.

Disconnect plug connection.

Release oxygen monitor sensor with special tool  11 7 030  in
conjunction with 11 9 150 .

Installation:

The threads of new oxygen monitor sensors are already
coated with Never Seez Compound.

If an oxygen monitor sensor is reused, only apply a thin and
uniform coat of Never Seez Compound (refer
to BMW Parts Service) to thread.

Oxygen monitor sensor section projecting into exhaust system
branch must not be cleaned or come into contact with
lubricant.

Cover oxygen monitor sensor when applying underseal. 

RA  Replacing oxygen monitor sensor (after primary catalytic converter) (N42/N46)

BMW AG - TIS

21.01.2013  14:30

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

2 RA Replacing Oxygen Monitor Sensor (after Primary Catalytic Converter) (N42_N46)|Page 768 > < 1 RA Replacing Both Oxygen Control Sensors (N42_N46)|Page 766