3 Series E46 316i (N42) TOUR
11 78 611
Replacing oxygen monitor sensor (after
primary catalytic converter) (N42/N46)
Special tools required:
•
11 7 030
•
11 9 150
Warning!
Scalding hazard!
Only perform this task on an engine that has cooled down.
Unclip cable and plug.
Disconnect plug connection.
Release oxygen monitor sensor with special tool 11 7 030 in
conjunction with 11 9 150 .
Installation:
The threads of new oxygen monitor sensors are already
coated with Never Seez Compound.
If an oxygen monitor sensor is reused, only apply a thin and
uniform coat of Never Seez Compound (refer
to BMW Parts Service) to thread.
Oxygen monitor sensor section projecting into exhaust system
branch must not be cleaned or come into contact with
lubricant.
Cover oxygen monitor sensor when applying underseal.
RA Replacing oxygen monitor sensor (after primary catalytic converter) (N42/N46)
BMW AG - TIS
21.01.2013 14:30
Issue status (12/2007) Valid only until next DVD is issued
Copyright