Replace the cap only after you have checked three times and
there is an incorrect opening pressure.
Checking pressure relief valve in cap:
Screw cap (1) onto special tool 17 0 114 .
Build up pressure with special tool (hand pump) 17 0 101 ;
observe pressure gauge to ascertain when opening pressure is
achieved.
Compare opening pressure of pressure relief valve.
RA Checking cooling system for water leaks