Press locks together of plugs (1) for glow elements.
Disconnect plugs.
Disconnect plug connection on crankshaft position sensor (2).
Disconnect plug connections on control unit for glow elements (1).
Note:
Connection from control unit to starter motor can remain.
Unfasten screws.
Remove cable channel.
Disconnect positive lead (1) and both control lines (2 and 3) on
starter.
Installation:
Tightening torque 12 41 4AZ
.
Disconnect plug connection on alternator.
RA Replacing wiring harness section for engine (M47TU)
BMW AG - TIS
11.02.2013 13:58
Issue status (12/2007) Valid only until next DVD is issued
Copyright