Unlock plug (1) and remove.

Grip at hexagon head (2) when removing pressure sensor.

Release hexagon screw connection (3) on pressure accumulator.

Installation:

Secure position of pressure regulator and grip at hexagon
fitting (2).

Tighten down hexagon screw connection (3).

Tightening torque 13 53 13AZ

.

Note:

Check stored fault messages.

Now clear the fault memory.

RA  Replacing pressure regulator on pressure accumulator of injection system (M47TU,