3 Series E46 318d (M47TU) TOUR
64 11 829
Replacing actuator drive of ventilation flaps
Remove and install housing for glovebox and cover on
equipment carrier at bottom,
refer to 51 45 030.
Remove and install actuator drive of defrosting flap,
refer to 64 11 845.
Disconnect plug connection (1). Unlock actuator drive (2) and
remove.
Installation:
If necessary, align shaft for defrosting flaps and drive (see
illustration).
RA Replacing actuator drive of ventilation flaps
BMW AG - TIS
14.02.2013 20:34
Issue status (12/2007) Valid only until next DVD is issued
Copyright