3 Series E46 318ti (N42) COMP
Installation:
When special tool 11 9 150 is used in conjunction with special
tool 11 7 030 , 47 Nm on the torque wrench dial corresponds
to an actual tightening torque of 50 Nm.
To tighten down oxygen monitor sensor, fit torque wrench and
special tools 11 7 030 / 11 9 150 as shown in illustration.
Tightening torque 11 78 1AZ .
Pay attention to cable routing for oxygen monitor sensor.
Check function of DME.
RA Replacing oxygen monitor sensor (after primary catalytic converter) (N42/N46)
BMW AG - TIS
12.02.2013 01:58
Issue status (12/2007) Valid only until next DVD is issued