Installation:

When special tool  11 9 150  is used in conjunction with special
tool  11 7 030 , 47 Nm on the torque wrench dial corresponds
to an actual tightening torque of 50 Nm.

To tighten down oxygen monitor sensor, fit torque wrench and
special tools  11 7 030  /  11 9 150  as shown in illustration.

Tightening torque 11 78 1AZ .

Pay attention to cable routing for oxygen monitor sensor.

Check function of DME.

RA  Replacing oxygen monitor sensor (after primary catalytic converter) (N42/N46)

BMW AG - TIS

12.02.2013  01:58

Issue status (12/2007) Valid only until next DVD is issued