Release positive lead from retaining clip.

Release positive leads from terminal to alternator (1) and from
alternator to starter motor (2).

Note:

Line (3) leads to auxiliary heater.

Installation:

Tightening torque, 12 31 1AZ.

Disconnect battery negative lead (1) to alternator at solenoid
switch of starter motor.

Tightening torque, 12 41 4AZ.

Note:

Read out fault memory of DDE control unit.

Check stored fault messages.

Rectify faults.

Then clear fault memory.