3 Series E46 320i (M52TU) SAL
17 00 039
Venting cooling system and checking for
leaks M52TU
Warning!
Danger of scalding, cap should only be opened when the
engine is cooled down.
Top up cooling system, bleed cooling system,
refer to 17 00 005
Check cooling system for water tightness,
refer to 17 00 009
Set heater control to maximum temperature and set fan to low
speed. This opens the heating valves.
Run engine and flush out engine cooling circuit with three or four
short bursts of throttle (approx. 4500 to 5000 rpm) (sealing cap
open). While doing so, do not run engine for longer than approx.
30 sec. to prevent coolant from heating up and expanding.
It is not necessary to warm up the engine since the thermostat is
vented through a bore.
Coolant level check
To check coolant level, allow engine to cool down; coolant
temperature may not exceed 30
°
C. If ambient temperature is
above 30
°
C, then allow engine to cool down at least to ambient
temperature.
Check coolant level, top up coolant if necessary until float (1) is in
line with top edge of expansion tank.
Note:
Tank mark indicates the fluid level at approx. 20
°
C.
RA Venting cooling system and checking for leaks M52TU
BMW AG - TIS
13.02.2013 01:13
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -