bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

7 RA Conducting Leak Test On Fuel Tank And Tank Ventilation System|Page 899 > < 6 RA Checking Fuel Tank And Tank Venting System For Leaks With Tank Leakage Diagnosis|Page 897
Page 1
background image

16 00 510

Conducting leak test on fuel tank and tank
ventilation system

Note:

The following procedure is only applicable to vehicles with the
tank leak diagnosis module (DM-TL).

Caution!

On vehicles with tank leak diagnosis modules (DM-TL), do not
work with external pressurization as the tank venting system
will leak under this condition.

On account of emerging fuel vapors, carry out all work in well
ventilated rooms. Or use a suitable extractor system.

Observe country-specific accident prevention and
occupational safety regulations.

In the Diagnosis and Information System (DIS), go to the
"Function and component selection" page.

By selecting:

-

Service functions

-

Drive

-

Digital Motor Electronics

-

Activation DMTL pump

adopt test module in test schedule.

Switch to the test schedule and implement the "Activation DMTL
pump" test module. 

Tank leak diagnosis pump pressurizes fuel tank and tank venting
system.

Carry out leak test.

Terminate test module after completing leak test.

Note:

Tank leak diagnosis pump is automatically shut down after
approx. 15 minutes due to risk of overheating. Allow pump to cool
down for at least 15 minutes. Then continue procedure.

RA  Conducting leak test on fuel tank and tank ventilation system

BMW AG - TIS

15.02.2013  04:44

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

7 RA Conducting Leak Test On Fuel Tank And Tank Ventilation System|Page 899 > < 6 RA Checking Fuel Tank And Tank Venting System For Leaks With Tank Leakage Diagnosis|Page 897