bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

3 RA Replacing Safety Battery Terminal (SBK) > < 2 RA Replacing Battery Positive Lead (between Starter Motor And Alternator) (M54 _ M5
Page 2
background image

Unscrew nut (1).

Installation:

Tightening torque 12 41 4AZ

.

Disconnect battery positive lead (2) from starter motor.

Remove battery positive lead.

E39 only:

Release screw connection of battery positive lead (1) (floorpan).

Release nut on starter motor (3).

Installation:

Tightening torque 12 41 4AZ

.

Detach battery positive lead (1) from holder (2).

Read out fault memory of DME control unit

Check stored faults

Rectify faults

Clear fault memory

RA  Replacing battery positive lead (between starter motor and alternator) (M54 / M5

BMW AG - TIS

16.02.2013  07:32

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

3 RA Replacing Safety Battery Terminal (SBK) > < 2 RA Replacing Battery Positive Lead (between Starter Motor And Alternator) (M54 _ M5