bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

2 RA Replacing Both Oxygen Monitor Sensors (S54)|Page 703 > < 1 RA Replacing Both Oxygen Control Sensors (S54)|Page 701
Page 1
background image

11 78 613

Replacing both oxygen monitor sensors (S54)

Special tools required:

11 7 020

11 7 030

11 9 150

(for work step number 13 00 002)

US version:

In the US version, the oxygen monitor sensors are installed in the
exhaust manifolds.

Cylinders 1 to 3:

Release monitor sensor with special tool 

11 9 150  in conjunction with special tool  11 7 030  and
tighten down.

Installation:

When special tool  11 9 150  is used in conjunction with special
tool  11 7 030 , 47 Nm on the torque wrench dial corresponds
to an actual tightening torque of 50 Nm.

Cylinders 4 to 6:

Release monitor sensor with special tool 

11 7 020  and tighten down.

Tightening torque, 11 78 1AZ.

ECE version:

Remove catalytic converter.

Unclip oxygen monitor sensor cable from holder.

To release and tighten down oxygen monitor sensors (1), use
special tool  11 7 020  or special tool  11 7 030 .

Tightening torque, 11 78 1AZ.

RA  Replacing both oxygen monitor sensors (S54)

BMW AG - TIS

16.02.2013  15:48

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

2 RA Replacing Both Oxygen Monitor Sensors (S54)|Page 703 > < 1 RA Replacing Both Oxygen Control Sensors (S54)|Page 701