12 42 510

Replacing battery positive lead (between
starter motor and B+ support point) (S54)

Read fault memory. Switch off ignition.

Observe safety instructions for handling vehicle battery.

Remove front underbody protection.

Observe instructions for disconnecting and connecting battery.

Disconnect battery negative lead from battery and lay to one side.

Unclip battery positive lead from clips (1).

Feed battery positive lead out of cable duct.

Fold back protective cap (1).

Release nut (2).

Installation:

Tightening torque, 12 51 4AZ.

Disconnect battery positive lead (3) from connection point.