13 90 500

Replacing tank venting valve (S54)

Turn off ignition.

Note:

Tank venting valve is fitted at front under intake air manifold.

Remove intake filter housing.

Unlock plug (2) and detach from tank venting valve (1).

Press locking bar (4) and detach vent hose (3).

Detach hose (5) from tank venting valve (1).

Detach tank venting valve (1) with rubber holder together with
intake air manifold.

Note:

Read out fault memory of DME control unit.

Check stored fault messages.

Rectify faults.

Now clear the fault memory.