background image

Remove hose (1) for engine vent.

Remove sealing cap (2).

Remove ignition coil cover.

Note:

The plug housings of the oxygen sensors for cylinders 1 to 3
and 4 to 6 are different.

Unclip plug housing (1) from mounting.

Disconnect plug connections of oxygen sensors.

Feed oxygen sensor cables out of shield plate of exhaust
manifold.

Installation:

Clip cables of oxygen sensors into mounts on shield plate of
exhaust manifold.

Caution!

Ensure cables are exactly routed.

Note:

Fig. shows US version.

Remove underbody protection.

E46 only:

Remove reinforcement plate.

Caution!

The section "Removing and installing reinforcement plate"
contains important installation instructions.