3 Series E46 M3 (S54) CONVER
Installation:
Ensure seal (1) is in correct installation position.
Remove dust cap (1).
Connect special tool kit 13 5 220 (comprising 13 5 221 and
13 5 222 ) to pressure sensor of DIS Tester.
Connect pressure sensor to DIS Tester.
Caution!
Do not under any circumstances screw in the check valve up
to the mechanical stop.
This could damage the valve in the pressure regulator
housing.
RA Checking fuel pump delivery pressure (S54)
BMW AG - TIS
16.02.2013 09:54
Issue status (12/2007) Valid only until next DVD is issued
Copyright