Release screws (1, 2, 3).

Remove control unit for left xenon light.

Remove air cleaner.

Caution!

When working on the oil, coolant or fuel circuit, you must
protect the alternator against contamination.

Cover alternator with suitable materials.

Failure to comply with this procedure may result in an
alternator malfunction.

Remove holder from oil cooler line (1).

Release oil cooler line (1) on oil filter housing.

Catch and dispose of escaping oil.