bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

2 RA Replacing Oxygen Monitor Sensor (after Main Catalytic Converter) (N45T) > < 1 RA Replacing Oxygen Sensor (N45T)
Page 2
background image

Release cable from holders (1).

Release oxygen sensor with special tool 11 4 260  from below.

Tightening torque  11 78 1AZ.

Installation:

Threads of new oxygen sensors are already coated with
Never Seez Compound.

If an oxygen sensor is reused, only apply a thin and uniform
coat of Never Seez Compound (refer to BMW Parts
Service) to thread.

Do not clean the oxygen sensor section which protrudes into
the exhaust line and ensure that it avoids all contact with
lubricants.

Installation:

Protect (mask) oxygen sensor when applying underseal. 

Pay attention to cable routing of oxygen sensor.

Check function of DME.

RA  Replacing oxygen sensor (N45T)

BMW AG - TIS

19.01.2013  01:19

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -