Determine measurement C, thickness of shim.
Installation:
Calculate thickness of new shim:
1.
Add measurement A of output flange (previous) and
measurement C of shim (previous)
Then subtract measurement B (previous) from
result A+C (previous)
2.
Subtract measurement B from measurement A of output
flange (new)
3.
Then subtract result of step 2 from result of step 1.
RA Replacing output flange on transfer case at rear (ATC300)
BMW AG - TIS
13.02.2013 00:08
Issue status (12/2007) Valid only until next DVD is issued
Copyright